Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 196
Filtrar
1.
BMC Med Educ ; 24(1): 290, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38491487

RESUMO

BACKGROUND: To compare the value and efficiency of the three-dimensional (3D) heads-up surgical system and traditional microscopic (TM) system in teaching and learning vitreoretinal surgeries. METHODS: Twenty ophthalmologists and scrub nurses were recruited as teachers, and 45 junior ophthalmology residents and trainee doctors, trainee nurses, and medical students were recruited as observers. Each teacher and observer were assigned to both a 3D-assisted and TM-assisted vitreoretinal surgery and then asked to complete satisfaction questionnaires for both surgical systems at the end of each surgery. RESULTS: The 3D heads-up surgical system was rated significantly higher in most of the subscales and overall satisfaction score by both teachers and observers (P < 0.05). However, ratings for instrument adjustment were significantly higher in the TM group compared to the 3D group for junior ophthalmology residents and trainee doctors (6.1 ± 1.7 vs. 8.8 ± 1.1, P < 0.001). CONCLUSIONS: The 3D heads-up surgical system has great didactical value in the medical education of vitreoretinal surgeries, but it is important to consider the specific needs of different learners when choosing between the two systems. TRIAL REGISTRATION: Not applicable.


Assuntos
Educação Médica , Cirurgia Vitreorretiniana , Humanos , Cirurgia Vitreorretiniana/métodos , Estudos Prospectivos , Aprendizagem , Inquéritos e Questionários
2.
Vestn Oftalmol ; 139(5): 113-120, 2023.
Artigo em Russo | MEDLINE | ID: mdl-37942605

RESUMO

This article reviews literature on the use of intraoperative optical coherence tomography (iOCT) in vitreoretinal surgery, describes the historical aspects of the development of this technology from portable devices to optical coherence tomographs integrated into the surgical microscope, considers the advantages, limitations and disadvantages of this technology, which are now becoming obvious due to the accumulated experience. The review also explores the prospects for the development of iOCT and possible ways to solve its problems. In addition, the review presents and systematizes clinical findings that can be revealed with iOCT in such diseases as rhegmatogenous retinal detachment, complications of proliferative diabetic retinopathy, macular pathology, etc.


Assuntos
Retinopatia Diabética , Oftalmologia , Descolamento Retiniano , Cirurgia Vitreorretiniana , Humanos , Cirurgia Vitreorretiniana/efeitos adversos , Cirurgia Vitreorretiniana/métodos , Tomografia de Coerência Óptica/métodos , Descolamento Retiniano/cirurgia , Retinopatia Diabética/diagnóstico por imagem , Retinopatia Diabética/cirurgia
3.
Indian J Ophthalmol ; 71(11): 3544-3551, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37870022

RESUMO

Purpose: We evaluated the anatomical and functional outcomes after vitreoretinal surgery for complex retinal capillary hemangioblastoma (RCH). Methods: This was a retrospective case series of 15 patients (16 eyes) with tractional or combined retinal detachment (RD) managed with pars plana vitrectomy and tumor endoresection (ER) with/without feeder vessel ligation. Results: The mean age at the time of surgery was 30 years (range, 14-46 years). The most common tumor locations were inferotemporal (six eyes) and temporal (six eyes) quadrants. Indications for surgery included exudative RD with fibrovascular proliferation (eight eyes), combined RD (five eyes), vitreous hemorrhage (four eyes), and rhegmatogenous RD (two eyes). Tumor destruction was performed with laser and/or cryotherapy in nine eyes (57%) and ER in seven eyes (43%). Feeder vessel was ligated and cauterized in 10 (63%) and six eyes (37%), respectively. Anatomical success after initial surgery was 50% (eight eyes), which improved to 88% (14 eyes) after they underwent a repeat procedure for recurrent RD (eight eyes). At the last visit, visual acuity improved in seven eyes (44%), was stable in four eyes (25%), and worsened in five eyes (31%) with a mean follow-up of 29 months (6-79 months). Comparison between the ER group and the laser/cryotherapy group revealed no significant difference in final retinal reattachment rate (89% vs. 86%, P > 0.05), with better visual outcomes in laser/cryotherapy group (57% vs. 78%, P < 0.05). Conclusion: Pars plana vitrectomy with/without tumor endoresection can be a safe and effective treatment option for complex RCHs, achieving good tumor control and anatomical success with limited functional success.


Assuntos
Hemangioblastoma , Descolamento Retiniano , Neoplasias da Retina , Cirurgia Vitreorretiniana , Humanos , Adolescente , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Hemangioblastoma/diagnóstico , Hemangioblastoma/cirurgia , Cirurgia Vitreorretiniana/métodos , Estudos Retrospectivos , Retina , Neoplasias da Retina/diagnóstico , Neoplasias da Retina/cirurgia , Descolamento Retiniano/cirurgia , Vitrectomia , Resultado do Tratamento
4.
Expert Rev Med Devices ; 20(8): 651-672, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37394991

RESUMO

INTRODUCTION: Recent technologies and new devices continue to be developed in vitreoretinal surgeries, and they provide more details, enhance safety, improve surgeons' comfort, and better visual and anatomical outcomes. Some devices have been used for better visualization during surgery, and some help the operation performance. They are divided into the following titles: Intraoperative OCT (including hand-held, probe-integrated, and microscope-integrated OCT), three-dimensional visualization system, virtual reality system, endoscopic vitrectomy (fiber optics and non-fiber optics), wide-angle viewing systems (contact and non-contact lenses), endo-illumination, light filters, chromovitrectomy, the retinal prosthesis (including epiretinal, subretinal, and suprachoroidal devices), robot-assisted vitreoretinal surgery, newer Vitreoretinal instruments, gene and cell therapy. AREAS COVERED: In this narrative review, we focused on PubMed articles between 2010-2023 with these keywords: 'Optical Coherence Tomography,' 'Three-Dimensional,' 'Virtual System,' 'intraoperative,' 'endoscopic,' 'vitrectomy,' 'lens,' 'illumination,' 'filters,' 'chromovitrectomy,' 'prosthesis,' 'robotic surgery,' 'instrument,' 'gene,' 'cell.' EXPERT OPINION: The main aim of this review is to update the reader on the latest progression in intraoperative imaging and surgical vision technologies and to provide an understanding of how each has helped improve operation and surgical outcomes. The surgeons should know recent updates to do their best and achieve the most excellent results.


Assuntos
Cirurgiões , Cirurgia Vitreorretiniana , Humanos , Cirurgia Vitreorretiniana/métodos , Tomografia de Coerência Óptica/métodos , Microscopia , Tecnologia de Fibra Óptica
5.
BMC Ophthalmol ; 23(1): 282, 2023 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-37332012

RESUMO

BACKGROUND: Information regarding incidence of treatment plan changes may be useful when discussing postoperative treatment plans for patients. Moreover, it may help establish a standardized postoperative treatment plan. This study aimed to evaluate the incidence of early complications requiring treatment plan changes in patients following vitreoretinal surgery and investigate its risk factors. METHODS: This single-center retrospective study included 465 patients who had undergone vitreoretinal surgery. The reasons, incidence, and timing of treatment plan changes within 14 days of surgery were identified. Potential factors associated with the changes, such as patient demographics, surgeon's experience, diagnoses, and type of surgery were also analyzed. RESULTS: The treatment plan was changed in 76 patients (16.3%) at a mean of 4.0 ± 3.2 days after vitreoretinal surgery. The reasons for the plan changes were increased intraocular pressure (IIOP) in 66(86.8%), intraocular inflammation in 2(2.6%), corneal edema in 3(3.9%), leakage from the sclerotomy wound in 3(3.9%) patients, and combined IIOP and intraocular inflammation in 2(2.6%). The date of discharge was postponed because of treatment plan changes in 17 patients (22.4%). The incidence of plan changes was higher in patients who underwent gas or oil tamponade (P < 0.001) and those who underwent surgery performed by less experienced surgeons (P = 0.034). CONCLUSIONS: Treatment plan was changed in 16.3% of patients after vitreoretinal surgery. The risk of treatment plan changes was associated with the surgeon's experience in vitreoretinal surgery and the type of surgery. These results should be considered when establishing standardized care plans for patients who require vitreoretinal surgery.


Assuntos
Glaucoma , Cirurgia Vitreorretiniana , Humanos , Estudos Retrospectivos , Cirurgia Vitreorretiniana/métodos , Incidência , Vitrectomia/métodos , Glaucoma/etiologia , Inflamação , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia
6.
Rom J Ophthalmol ; 66(1): 55-60, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35531452

RESUMO

Objective. To evaluate the utility of intraoperative OCT and its influence on the surgeon's decision during vitreoretinal surgery. Methods. This was a pilot, prospective case series conducted at a tertiary care ophthalmology department in Lahore, Pakistan. Sixteen patients undergoing vitreoretinal surgeries were included using the Leica Enfocus microscope integrated intraoperative optical coherence tomography (IOCT). We also investigated the changes in surgical decision making based on the findings revealed by IOCT using a questionnaire. Results. 16 patients with a mean age of 40.6 ± 19.0 (range: 11-66) years, were included in the study; one case of acute postoperative endophthalmitis could not be imaged. The surgeon had to modify surgical decisions in four (26.7%) cases. IOCT clearly delineated various tissue planes for efficient and safe surgical dissection in pathologies such as posterior vitreous detachment, vitreomacular traction and epiretinal membranes. Furthermore, it also helped identifying perfluorocarbon-retina interface. Conclusions. The intraoperative OCT modality is a feasible and useful intraoperative imaging technique for various kinds of vitreoretinal disorders. The decision making of the surgeon was modified in a quarter of the cases after the use of this newer modality.


Assuntos
Membrana Epirretiniana , Oftalmologia , Cirurgia Vitreorretiniana , Adulto , Tomada de Decisões , Humanos , Pessoa de Meia-Idade , Tomografia de Coerência Óptica/métodos , Cirurgia Vitreorretiniana/métodos , Adulto Jovem
7.
Arch. Soc. Esp. Oftalmol ; 97(4): 219-223, abr. 2022. ilus
Artigo em Espanhol | IBECS | ID: ibc-208842

RESUMO

El agujero macular de espesor total es una complicación rara de la telangiectasia macular tipo 2, y su tratamiento es aún controvertido. Una paciente con esta entidad fue llevada a cirugía vitreorretiniana con aplicación de membrana de plasma rico en factores de crecimiento sobre el agujero macular. Al sexto mes de cirugía se logró mejoría anatómica y funcional, sin efectos adversos asociados. El plasma rico en factores de crecimiento es una alternativa nueva en el tratamiento quirúrgico del agujero macular atípico y/o persistente, que logra buenos resultados en términos de seguridad efectividad, debido a sus propiedades biológicas (AU)


Full-thickness macular hole is a rare complication of macular telangiectasia type 2, and its treatment is still controversial. A patient with a full-thickness macular hole secondary to macular telangiectasia type 2 underwent vitreoretinal surgery with a plasma rich in growth factors membrane in the macular hole. At the sixth month of follow-up, anatomical and functional improvements were achieved, with no adverse effects. Plasma rich in growth factors is a new option, with advantages due to its biological properties that achieves good results in terms of safety and effectiveness in the surgical treatment of macular holey (AU)


Assuntos
Humanos , Feminino , Idoso , Perfurações Retinianas/etiologia , Perfurações Retinianas/cirurgia , Telangiectasia Retiniana/complicações , Cirurgia Vitreorretiniana/métodos , Fatores de Crescimento Transformadores/administração & dosagem , Plasma , Resultado do Tratamento
8.
Indian J Ophthalmol ; 70(2): 477-481, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35086220

RESUMO

PURPOSE: To study the role of digitally assisted vitreoretinal surgery (DAVS) as a learning and teaching tool compared to that of the standard binocular side-scope of the conventional analog microscope (CAM). METHODS: This was a cross-sectional, observational study conducted at a tertiary eye care center and teaching institute in South India. Postgraduate residents and clinical fellows observed a predecided set of retinal surgical procedures using both DAVS and CAM. A detailed questionnaire was used to compare the participants' subjective scoring of both the platforms in terms of level of comfort, clarity of image and stereopsis, level of understanding, and overall impression. RESULTS: Thirty-six participants, including 20 residents and 16 fellows, took part in this study. DAVS obtained a higher score for all 15 questions compared to CAM and the differences were statistically significant. DAVS obtained a mean score of 4.80 (median: 5) whereas CAM obtained a mean score of 3.14 (median: 3) on a grading scale of 1-5 with regard to the overall experience of surgical viewing through either platform (P < 0.01). CONCLUSION: DAVS is a better learning and teaching tool compared to the side scope of the CAM from a learner's perspective. Thus, DAVS can help beginners in the field of vitreoretinal surgery obtain a better understanding of the surgical steps prior to the initiation of hands-on training.


Assuntos
Internato e Residência , Oftalmologia , Cirurgia Assistida por Computador , Cirurgia Vitreorretiniana , Competência Clínica , Estudos Transversais , Humanos , Procedimentos Cirúrgicos Oftalmológicos , Oftalmologia/educação , Cirurgia Assistida por Computador/métodos , Ensino , Cirurgia Vitreorretiniana/métodos
10.
Eye (Lond) ; 36(2): 379-391, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34272509

RESUMO

In this systematic review, we provide an overview of the current state of intraoperative optical coherence tomography (iOCT). As iOCT technology is increasingly utilized, its current clinical applications and potential uses warrant attention. Here, we categorize the findings of various studies by their respective fields, including the use of iOCT in vitreoretinal surgery, corneal surgery, glaucoma surgery, cataract surgery, and pediatric ophthalmology. The trend observed in recent decades towards performing minimally invasive ophthalmic surgery has caused practitioners to recognize the limitations of using a conventional surgical microscope for intraoperative visualization. Thus, the superior visualization provided by iOCT can improve the safety of these surgical techniques and promote the development of new minimally invasive ophthalmic surgeries. Landmark prospective studies found that iOCT can significantly affect surgical decision making and can cause a subsequent change in surgical strategy, and the use of iOCT has potential to improve surgical outcome. Despite these advantages, however, iOCT is still a relatively new technique, and beginning users of iOCT can encounter limitations that can preclude their reaching the full potential of iOCT and in this respect several improvements are needed.


Assuntos
Tomografia de Coerência Óptica , Cirurgia Vitreorretiniana , Criança , Córnea , Humanos , Procedimentos Cirúrgicos Oftalmológicos , Estudos Prospectivos , Tomografia de Coerência Óptica/métodos , Cirurgia Vitreorretiniana/métodos
11.
J Mater Chem B ; 9(44): 9162-9173, 2021 11 17.
Artigo em Inglês | MEDLINE | ID: mdl-34697622

RESUMO

Polymer-based hydrogels used in the vitreous cavity could lead to an unsatisfactory gel-forming state, uncontrollable swelling, and potential cytotoxicity. Their application can significantly impair the filling effect and cause severe side effects in the surrounding tissues. To address the concerns, a poly(ethylene glycol)-engineered hydrogel capable of fast in situ gel formation (less than 1 min), with an ultralow swelling ratio and no cytotoxicity in the rabbits' eyes, was constructed as a vitreous substitute. The multi-arm polyethylene glycols (PEGs) modified with functional groups (thiol and maleimide) possess high reaction efficiency in the vitreous cavity and present excellent biomimetic characteristics of the natural vitreous humor in vitro. After injection with a double syringe via a 25-gauge needle in the eyes of rabbits for 6 months, the hydrogel functioned as an artificial vitreous body that could highly promote retinal detachment repair, with excellent biocompatibility and high transparency, and without bio-degradation or ocular complications. Collectively, the fast in situ forming hydrogel could achieve quick and good filling in the vitreous cavity without cytotoxicity, which makes it a promising long-term endotamponade substitute.


Assuntos
Tamponamento Interno/métodos , Hidrogéis/uso terapêutico , Polietilenoglicóis/uso terapêutico , Descolamento Retiniano/tratamento farmacológico , Animais , Hidrogéis/síntese química , Hidrogéis/toxicidade , Polietilenoglicóis/síntese química , Polietilenoglicóis/toxicidade , Coelhos , Cirurgia Vitreorretiniana/métodos , Corpo Vítreo/cirurgia
12.
Int J Mol Sci ; 22(18)2021 Sep 17.
Artigo em Inglês | MEDLINE | ID: mdl-34576231

RESUMO

Toxic tumour syndrome (TTS) is a particularly aggressive form of secondary vasculopathy occurring after radiation therapy of uveal melanoma due to the persistence of the necrotic tumour mass inside the eye. The development of TTS confers a particularly unfavourable functional and anatomical ocular prognosis, ultimately requiring enucleation in most cases if untreated. Vitreoretinal (VR) surgery has been successfully applied for treatment and prevention of TTS using both resecting and non-resecting techniques. In this systematic review, we aim to define characteristics of uveal melanomas benefiting the most from secondary VR surgery and to outline the optimal type and timing of VR intervention in such cases. Analysis of the literature reveals that endoresection should be performed within 3 months after radiotherapy to tumours thicker than 7 mm and with a largest basal diameter between 8 mm and 15 mm with post-equatorial location, especially after proton beam treatment. Alternatively, endodrainage remains a valid therapeutic option in eyes with macula-off retinal detachment, tumour diameter larger than 15 mm or ciliary body involvement. VR surgery can be successful in the management of TTS following radiotherapy for uveal melanoma when timing and indication are appropriately evaluated.


Assuntos
Transtornos Cerebrovasculares/prevenção & controle , Neoplasias da Coroide/radioterapia , Neoplasias da Coroide/cirurgia , Melanoma/radioterapia , Melanoma/cirurgia , Neoplasias Uveais/radioterapia , Neoplasias Uveais/cirurgia , Cirurgia Vitreorretiniana/métodos , Neoplasias da Coroide/patologia , Corpo Ciliar , Humanos , Melanoma/patologia , Prognóstico , Terapia com Prótons , Radioterapia/efeitos adversos , Descolamento Retiniano/patologia , Neoplasias Uveais/patologia , Acuidade Visual
13.
Dev Ophthalmol ; 61: 15-25, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33647898

RESUMO

Intraoperative portable handheld and microscope-integrated OCT enhance the pediatric vitreoretinal surgeon's diagnostic abilities during examination under anesthesia and surgery, particularly in children who are challenging to examine preoperatively due to young age or ocular trauma. Improved OCT-guided visualization of vitreoretinal anatomic relationships has the potential to improve surgical safety and efficiency. In retinopathy of prematurity and other pediatric retinal vascular conditions, intraoperative OCT can be critical for distinguishing between retinoschisis and retinal detachment and highlighting abnormalities of the vitreoretinal interface that may contribute to development of tractional retinal detachments. During retinal detachment repair, intraoperative OCT aids identification of subtle retinal breaks, residual subretinal fluid, retained perfluorocarbon, preretinal membranes, and residual hyaloid, among other findings. In macular surgery, intraoperative OCT has demonstrated value in confirming completion or lack thereof of epiretinal and internal limiting membrane peeling and differentiating between lamellar and full-thickness macular holes. OCT-guided subretinal bleb formation and genetic vector delivery are critical to ensuring accurate localization of subretinal gene delivery for inherited retinal degenerations. Research on development of OCT-compatible surgical instruments, real-time three-dimensional volumetric OCT imaging, and integration with intraoperative OCT angiography are anticipated to further increase the utility of intraoperative OCT in pediatric vitreoretinal surgical decision-making.


Assuntos
Retina/diagnóstico por imagem , Doenças Retinianas/cirurgia , Cirurgia Assistida por Computador/métodos , Tomografia de Coerência Óptica/métodos , Cirurgia Vitreorretiniana/métodos , Criança , Humanos , Retina/cirurgia , Doenças Retinianas/diagnóstico
14.
J Med Case Rep ; 15(1): 16, 2021 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-33468218

RESUMO

BACKGROUND: Use of perfluorocarbon liquid (PFCL) has been increasingly growing as an adjuvant in vitreo-retina surgeries. Some commonly encountered complications with its use include subretinal migration, formation of sticky silicone oil or retained PFCL in vitreous cavity and anterior chamber. Scleral rupture during PFCL injection has a rare occurrence. We report an unexpected event of scleral rupture during PFCL injection and discuss the management challenges faced by the surgeon. CASE PRESENTATION: A 66 year indo-aryan male was undergoing pars-plana vitrectomy (PPV) with diagnosis of subtotal rhegmatogenous retinal detachment (RD) with Proliferative Vitreo-retonipathy (PVR)-B. After near total vitrectomy PFCL was being injected and then there was sudden poor visualization of fundus with development of bullous RD and globe hypotony. The surgeon was not able to figure out the cause of hypotony and air was switched on in the infusion cannula. This further complicated the situation resulting in migration of air in the anterior chamber, posterior dislocation of intraocular lens complex, 180° inferior retinal dialysis and ballooning of the conjunctiva which gave a clue of probable scleral rupture. Conjunctival peritomy was performed superiorly and scleral defect was noted. Intraocular tissue incarceration and air leak was visible from the wound. This confirmed scleral rupture during PFCL injection. Repositioning of incarcerated retina was not possible and retinectomy was performed followed by repair of scleral rupture with lots of difficulty in a vitrectomised eye. CONCLUSION: PFCL injection, a crucial step of vitreoretina surgery, should be performed slowly with extreme caution maintaining an optimal intraocular pressure to prevent devastating complications like scleral rupture.


Assuntos
Fluorocarbonos/administração & dosagem , Complicações Intraoperatórias/etiologia , Injeções Intravítreas/efeitos adversos , Descolamento Retiniano/cirurgia , Ruptura/etiologia , Esclera/lesões , Vitrectomia/métodos , Vitreorretinopatia Proliferativa/cirurgia , Idoso , Traumatismos Oculares/etiologia , Humanos , Masculino , Cirurgia Vitreorretiniana/métodos
15.
Sci Rep ; 11(1): 599, 2021 01 12.
Artigo em Inglês | MEDLINE | ID: mdl-33436689

RESUMO

Serious intraocular toxicity cases have been reported worldwide after the use of different perfluorocarbon liquids. The current study reports for the first-time the clinical pictures of cases of acute intraocular toxicity caused by MEROCTANE, a perfluoro-octane commercialized by a Turkish company and distributed in many countries. A series of 18 cases from Chile and Spain was retrospectively analysed. To evaluate the impurity profile, a suspicious MEROCTANE sample (lot OCT.01.2013) was analysed by gas chromatography mass spectrometry and compared with a non-suspicious sample of the same commercial perfluoro-octane (lot OCT 722011). Cytotoxicity was tested following a direct-contact method, taking into consideration the high volatility and hydrophobicity of perfluoro-octane and following the ISO 10993 guideline. Cytotoxicity test showed clear cytotoxic effects of the analysed batch (less than 9% of cell viability). Moreover, chemical analysis demonstrated the presence of many contaminants, some highly toxic (acids and alcohols). Perfluorocarbon liquids are useful tools for intraocular surgery but companies and Agencies of Medical Devices must implement measures that guarantee the safety of these products based on both chemical and cytotoxicity analysis for every batch. Medical staff should be encouraged to report any suspected case to their respective National Agencies.


Assuntos
Fluorocarbonos/efeitos adversos , Descolamento Retiniano/cirurgia , Epitélio Pigmentado da Retina/patologia , Testes de Toxicidade/métodos , Acuidade Visual/efeitos dos fármacos , Cirurgia Vitreorretiniana/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Sobrevivência Celular , Células Cultivadas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Epitélio Pigmentado da Retina/efeitos dos fármacos , Epitélio Pigmentado da Retina/metabolismo , Estudos Retrospectivos
16.
Acta Ophthalmol ; 99(3): 240-250, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-32930501

RESUMO

Silicone oil (SO) has been used as a long-term tamponade agent in the treatment of complicated vitreoretinal diseases for about half a century, during which time many advances in surgical techniques and technologies have been made. This review summarizes the chemical and physical properties of SO, its indications and complications, including particularly emulsification. The mechanisms and risk factors for emulsification are discussed, as well as novel strategies for its effective removal. Finally, the review focuses on new improved formulations of SO, including research into slow-release pharmacological agents within SO and provides an overview of alternatives to SO for the purpose of long-term tamponade that are being developed.


Assuntos
Tamponamento Interno/métodos , Óleos de Silicone/administração & dosagem , Humanos , Óleos de Silicone/efeitos adversos , Óleos de Silicone/química , Cirurgia Vitreorretiniana/métodos
17.
Acta Ophthalmol ; 99(3): e346-e351, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-32840059

RESUMO

PURPOSE: To evaluate a 3-D visualization helmet (3DVH) during 23-gauge pars plana vitrectomy (PPV) for macular holes (MH) and macular puckers (MP). METHODS: A total of 184 eyes of 184 patients undergoing PPV for MH or MP were randomly selected for surgery with 3DVH or standard Galilean microscope (GM). Only one highly trained surgeon performed each PPV. A surgical comfort score, ranging from 1 to 10 was recorded after each operation. Statistical analysis was run with SPSS to compare parameters before and after surgery and between the two groups. RESULTS: No statistical differences were found between the two groups for mean best correct visual acuity improvement after surgery (p < 0.001). Mean surgery comfort evaluation was 7.63 ± 0.48 in 3DVH eyes and 8.21 ± 0.62 in GM ones (p = 0.09); mean overall surgical time was 35.12 ± 3.8 min in 3DVH eyes and 32.7 ± 2.27 min in GM ones (p < 0.001); mean peeling time was 14.24 ± 3.42 min in 3DVH eyes and 13.61 ± 4.63 min in GM ones (p = 0.11). CONCLUSIONS: According to the data observed in this study, the 3DVH provides adequate safety and efficacy in retinal and macular visualization during PPV for MH and MP.


Assuntos
Imageamento Tridimensional/instrumentação , Perfurações Retinianas/cirurgia , Vitrectomia/métodos , Idoso , Feminino , Humanos , Imageamento Tridimensional/normas , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Estudos Prospectivos , Vitrectomia/efeitos adversos , Cirurgia Vitreorretiniana/efeitos adversos , Cirurgia Vitreorretiniana/métodos
18.
Surv Ophthalmol ; 66(2): 198-212, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33278403

RESUMO

Endoscopy provides unique optical properties to circumvent anterior segment opacities and visualize difficult-to-access anatomical regions, including retroirideal, retrolental, ciliary body, and anterior retinal structures. We summarize the basic principles and utilization of endoscopic vitreoretinal surgery, along with recent technological advances in the field base on a structured literature search in Pubmed, Embase, and Google Scholar database up to February, 2020. Endoscopy has been used in the management of retinal detachment, ischemic retinopathies with neovascular glaucoma, severe ocular trauma, endophthalmitis, lens-related disorders in the posterior segment, pediatric vitreoretinal diseases, and implantation of retinal prostheses. Ongoing development of endoscopic technology aims to provide higher resolution images with endoscopes of smaller diameter. New surgical techniques supported by the adoption of endoscopy are available to manage challenging surgical scenarios. Endoscopy can be a useful adjunct to microscope wide-angle viewing systems in the management of complex vitreoretinal diseases.


Assuntos
Descolamento Retiniano , Doenças Retinianas , Cirurgia Vitreorretiniana , Criança , Endoscopia/métodos , Humanos , Descolamento Retiniano/cirurgia , Doenças Retinianas/cirurgia , Estudos Retrospectivos , Vitrectomia/métodos , Cirurgia Vitreorretiniana/métodos
19.
Asia Pac J Ophthalmol (Phila) ; 10(1): 26-38, 2020 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-33252365

RESUMO

ABSTRACT: Chromovitrectomy, the intraocular application of dyes to assist visualization of preretinal tissues during vitreoretinal surgery, was introduced to avoid ocular complications related to internal limiting membrane peeling, inadequate removal of the vitreous, and incomplete removal of epiretinal membranes. Since 2000, chromovitrectomy has become a popular approach among vitreoretinal specialists. The first vital dye used in chromovitrectomy, indocyanine green, facilitated identification of the fine and transparent internal limiting membrane. Following indocyanine green, trypan blue was introduced to identify epiretinal membranes, and triamcinolone acetonide stained the vitreous well. Recently, additional natural dyes such as lutein and anthocyanin from the açaí fruit have been proposed for intraocular application during vitrectomy. The main goal of this review was to study the role of vital stains in chromovitrectomy and report the latest findings in the literature.


Assuntos
Corantes/administração & dosagem , Vitrectomia/métodos , Cirurgia Vitreorretiniana/métodos , Corpo Vítreo/cirurgia , Membrana Epirretiniana/metabolismo , Humanos , Verde de Indocianina/administração & dosagem , Procedimentos Cirúrgicos Oftalmológicos , Coloração e Rotulagem/métodos , Azul Tripano/administração & dosagem
20.
Rev. bras. oftalmol ; 79(5): 294-295, set.-out. 2020. graf
Artigo em Inglês | LILACS | ID: biblio-1137982

RESUMO

Abstract This paper provides a fast and inexpensive technique to prevent slippage of the infusion cannula from the EVA DORC® 27-gauge system. After the usual retrobulbar anesthesia, antisepsis and asepsis, a 2% hydroxypropyl methylcellulose drop is placed around the infusion cannula in the trocar to hold it in position. This technique prevents the slippage of the infusion cannula and both the surgical time and creation of the first sclerotomy in the eye can be shortened slightly.


Resumo Este artigo fornece uma técnica rápida e barata para evitar o deslizamento da cânula de infusão do sistema EVA DORC® 27-gauge. Após a habitual anestesia retrobulbar, antissepsia e assepsia, uma gota de 2% de hidroxipropilmetilcelulose é colocada ao redor da cânula de infusão no trocater para mantê-la em posição. Essa técnica evita o deslizamento da cânula de infusão e o tempo cirúrgico e da criação da primeira esclerotomia no olho podem ser ligeiramente reduzidos.


Assuntos
Humanos , Vitrectomia/métodos , Procedimentos Cirúrgicos Minimamente Invasivos , Cirurgia Vitreorretiniana/métodos , Cânula
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...